Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
ACS Synth Biol ; 12(12): 3591-3607, 2023 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-37981737

RESUMO

In synthetic biology, Fluorescent reporters are frequently used to characterize the expression levels obtained from both genetic parts such as promoters and ribosome binding sites as well as from complex genetic circuits. To this end, plate readers offer an easy and high-throughput way of characterizing both the growth and fluorescence expression levels of cell cultures. However, despite the similar mode of action used in different devices, their output is not comparable due to intrinsic differences in their setup. Additionally, the generated output is expressed using arbitrary units, limiting reliable comparison of results to measurements taken within one single experiment using one specific plate reader, hampering the transferability of data across different plate readers and laboratories. This article presents an easy and accessible calibration method for transforming the device-specific output into a standardized output expressing the amount of fluorescence per well as a known equivalent fluorophore concentration per cell for fluorescent reporters spanning the visible light spectrum. This calibration method follows a 2-fold approach determining both the estimated number of cells and the equivalent chemical fluorophore concentration per well. It will contribute to the comparison of plate reader experiments between different laboratories across the world and will therefore greatly improve the reliability and exchange of both results and genetic parts between research groups.


Assuntos
Corantes Fluorescentes , Biologia Sintética , Reprodutibilidade dos Testes , Luz , Padrões de Referência
2.
Biodes Res ; 5: 0016, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37849456

RESUMO

Broad-host-range synthetic biology is an emerging frontier that aims to expand our current engineerable domain of microbial hosts for biodesign applications. As more novel species are brought to "model status," synthetic biologists are discovering that identically engineered genetic circuits can exhibit different performances depending on the organism it operates within, an observation referred to as the "chassis effect." It remains a major challenge to uncover which genome-encoded and biological determinants will underpin chassis effects that govern the performance of engineered genetic devices. In this study, we compared model and novel bacterial hosts to ask whether phylogenomic relatedness or similarity in host physiology is a better predictor of genetic circuit performance. This was accomplished using a comparative framework based on multivariate statistical approaches to systematically demonstrate the chassis effect and characterize the performance dynamics of a genetic inverter circuit operating within 6 Gammaproteobacteria. Our results solidify the notion that genetic devices are strongly impacted by the host context. Furthermore, we formally determined that hosts exhibiting more similar metrics of growth and molecular physiology also exhibit more similar performance of the genetic inverter, indicating that specific bacterial physiology underpins measurable chassis effects. The result of this study contributes to the field of broad-host-range synthetic biology by lending increased predictive power to the implementation of genetic devices in less-established microbial hosts.

3.
Synth Biol (Oxf) ; 7(1): ysac023, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36381610

RESUMO

Standardized deoxyribonucleic acid (DNA) assembly methods utilizing modular components provide a powerful framework to explore designs and iterate through Design-Build-Test-Learn cycles. Biopart Assembly Standard for Idempotent Cloning (BASIC) DNA assembly uses modular parts and linkers, is highly accurate, easy to automate, free for academic and commercial use and enables hierarchical assemblies through an idempotent format. These features enable applications including pathway engineering, ribosome binding site (RBS) tuning, fusion protein engineering and multiplexed guide ribonucleic acid (RNA) expression. In this work, we present basicsynbio, open-source software encompassing a Web App (https://basicsynbio.web.app/) and Python Package (https://github.com/LondonBiofoundry/basicsynbio), enabling BASIC construct design via simple drag-and-drop operations or programmatically. With basicsynbio, users can access commonly used BASIC parts and linkers while designing new parts and assemblies with exception handling for common errors. Users can export sequence data and create instructions for manual or acoustic liquid-handling platforms. Instruction generation relies on the BasicBuild Open Standard, which is parsed for bespoke workflows and is serializable in JavaScript Object Notation for transfer and storage. We demonstrate basicsynbio, assembling 30 vectors using sequences including modules from the Standard European Vector Architecture (SEVA). The BASIC SEVA vector collection is compatible with BASIC and Golden Gate using BsaI. Vectors contain one of six antibiotic resistance markers and five origins of replication from different compatibility groups. The collection is available via Addgene under an OpenMTA agreement. Furthermore, vector sequences are available from within the basicsynbio application programming interface with other collections of parts and linkers, providing a powerful environment for designing assemblies for bioengineering applications. Graphical Abstract.

4.
Synth Biol (Oxf) ; 7(1): ysac010, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35949424

RESUMO

Plate readers are commonly used to measure cell growth and fluorescence, yet the utility and reproducibility of plate reader data is limited by the fact that it is typically reported in arbitrary or relative units. We have previously established a robust serial dilution protocol for calibration of plate reader measurements of absorbance to estimated bacterial cell count and for green fluorescence from proteins expressed in bacterial cells to molecules of equivalent fluorescein. We now extend these protocols to calibration of red fluorescence to the sulforhodamine-101 fluorescent dye and blue fluorescence to Cascade Blue. Evaluating calibration efficacy via an interlaboratory study, we find that these calibrants do indeed provide comparable precision to the prior calibrants and that they enable effective cross-laboratory comparison of measurements of red and blue fluorescence from proteins expressed in bacterial cells.

5.
Nat Commun ; 13(1): 5082, 2022 08 29.
Artigo em Inglês | MEDLINE | ID: mdl-36038542

RESUMO

Here we introduce the Galaxy-SynBioCAD portal, a toolshed for synthetic biology, metabolic engineering, and industrial biotechnology. The tools and workflows currently shared on the portal enables one to build libraries of strains producing desired chemical targets covering an end-to-end metabolic pathway design and engineering process from the selection of strains and targets, the design of DNA parts to be assembled, to the generation of scripts driving liquid handlers for plasmid assembly and strain transformations. Standard formats like SBML and SBOL are used throughout to enforce the compatibility of the tools. In a study carried out at four different sites, we illustrate the link between pathway design and engineering with the building of a library of E. coli lycopene-producing strains. We also benchmark our workflows on literature and expert validated pathways. Overall, we find an 83% success rate in retrieving the validated pathways among the top 10 pathways generated by the workflows.


Assuntos
Escherichia coli , Biologia Sintética , Biotecnologia , Escherichia coli/genética , Engenharia Metabólica , Software
6.
Sci Adv ; 8(18): eabm5091, 2022 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-35507663

RESUMO

Synthetic biology research and its industrial applications rely on deterministic spatiotemporal control of gene expression. Recently, electrochemical control of gene expression has been demonstrated in electrogenetic systems (redox-responsive promoters used alongside redox inducers and electrodes), allowing for the direct integration of electronics with biological processes. However, the use of electrogenetic systems is limited by poor activity, tunability, and standardization. In this work, we developed a strong, unidirectional, redox-responsive promoter before deriving a mutant promoter library with a spectrum of strengths. We constructed genetic circuits with these parts and demonstrated their activation by multiple classes of redox molecules. Last, we demonstrated electrochemical activation of gene expression under aerobic conditions using a novel, modular bioelectrochemical device. These genetic and electrochemical tools facilitate the design and improve the performance of electrogenetic systems. Furthermore, the genetic design strategies used can be applied to other redox-responsive promoters to further expand the available tools for electrogenetics.

7.
Nucleic Acids Res ; 50(3): 1783-1793, 2022 02 22.
Artigo em Inglês | MEDLINE | ID: mdl-35061908

RESUMO

The rational design and realisation of simple-to-use genetic control elements that are modular, orthogonal and robust is essential to the construction of predictable and reliable biological systems of increasing complexity. To this effect, we introduce modular Artificial RNA interference (mARi), a rational, modular and extensible design framework that enables robust, portable and multiplexed post-transcriptional regulation of gene expression in Escherichia coli. The regulatory function of mARi was characterised in a range of relevant genetic contexts, demonstrating its independence from other genetic control elements and the gene of interest, and providing new insight into the design rules of RNA based regulation in E. coli, while a range of cellular contexts also demonstrated it to be independent of growth-phase and strain type. Importantly, the extensibility and orthogonality of mARi enables the simultaneous post-transcriptional regulation of multi-gene systems as both single-gene cassettes and poly-cistronic operons. To facilitate adoption, mARi was designed to be directly integrated into the modular BASIC DNA assembly framework. We anticipate that mARi-based genetic control within an extensible DNA assembly framework will facilitate metabolic engineering, layered genetic control, and advanced genetic circuit applications.


Assuntos
Escherichia coli , Engenharia Metabólica , Escherichia coli/genética , Escherichia coli/metabolismo , Regulação da Expressão Gênica , Redes Reguladoras de Genes , Engenharia Genética , Interferência de RNA
8.
PLoS One ; 16(6): e0252263, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34097703

RESUMO

Reproducibility is a key challenge of synthetic biology, but the foundation of reproducibility is only as solid as the reference materials it is built upon. Here we focus on the reproducibility of fluorescence measurements from bacteria transformed with engineered genetic constructs. This comparative analysis comprises three large interlaboratory studies using flow cytometry and plate readers, identical genetic constructs, and compatible unit calibration protocols. Across all three studies, we find similarly high precision in the calibrants used for plate readers. We also find that fluorescence measurements agree closely across the flow cytometry results and two years of plate reader results, with an average standard deviation of 1.52-fold, while the third year of plate reader results are consistently shifted by more than an order of magnitude, with an average shift of 28.9-fold. Analyzing possible sources of error indicates this shift is due to incorrect preparation of the fluorescein calibrant. These findings suggest that measuring fluorescence from engineered constructs is highly reproducible, but also that there is a critical need for access to quality controlled fluorescent calibrants for plate readers.


Assuntos
Bactérias/genética , Engenharia Genética/métodos , Calibragem , Citometria de Fluxo/métodos , Fluorescência , Reprodutibilidade dos Testes , Biologia Sintética/métodos
9.
Commun Biol ; 3(1): 640, 2020 Oct 27.
Artigo em Inglês | MEDLINE | ID: mdl-33110148

RESUMO

An amendment to this paper has been published and can be accessed via a link at the top of the paper.

10.
Synth Biol (Oxf) ; 5(1): ysaa010, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32995552

RESUMO

Multi-part DNA assembly is the physical starting point for many projects in Synthetic and Molecular Biology. The ability to explore a genetic design space by building extensive libraries of DNA constructs is essential for creating programmed biological systems. With multiple DNA assembly methods and standards adopted in the Synthetic Biology community, automation of the DNA assembly process is now receiving serious attention. Automation will enable larger builds using less researcher time, while increasing the accessible design space. However, these benefits currently incur high costs for both equipment and consumables. Here, we address this limitation by introducing low-cost DNA assembly with BASIC on OpenTrons (DNA-BOT). For this purpose, we developed an open-source software package and demonstrated the performance of DNA-BOT by simultaneously assembling 88 constructs composed of 10 genetic parts, evaluating the promoter, ribosome binding site and gene order design space for a three-gene operon. All 88 constructs were assembled with high accuracy, at a consumables cost of $1.50-$5.50 per construct. This illustrates the efficiency, accuracy and affordability of DNA-BOT, making it accessible for most labs and democratizing automated DNA assembly.

11.
Commun Biol ; 3(1): 512, 2020 09 17.
Artigo em Inglês | MEDLINE | ID: mdl-32943734

RESUMO

Optical density (OD) is widely used to estimate the density of cells in liquid culture, but cannot be compared between instruments without a standardized calibration protocol and is challenging to relate to actual cell count. We address this with an interlaboratory study comparing three simple, low-cost, and highly accessible OD calibration protocols across 244 laboratories, applied to eight strains of constitutive GFP-expressing E. coli. Based on our results, we recommend calibrating OD to estimated cell count using serial dilution of silica microspheres, which produces highly precise calibration (95.5% of residuals  <1.2-fold), is easily assessed for quality control, also assesses instrument effective linear range, and can be combined with fluorescence calibration to obtain units of Molecules of Equivalent Fluorescein (MEFL) per cell, allowing direct comparison and data fusion with flow cytometry measurements: in our study, fluorescence per cell measurements showed only a 1.07-fold mean difference between plate reader and flow cytometry data.


Assuntos
Carga Bacteriana/genética , Escherichia coli/crescimento & desenvolvimento , Citometria de Fluxo , Calibragem , Contagem de Células/métodos , Escherichia coli/genética , Fluorescência , Regulação Bacteriana da Expressão Gênica/genética
12.
Methods Mol Biol ; 2205: 239-253, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32809203

RESUMO

Biopart Assembly Standard for Idempotent Cloning (BASIC) is a simple, robust, and highly accurate DNA assembly method, which provides 99% correct assemblies for a typical four-part assembly, enabling high efficiency cloning workflows (Storch et al., ACS Synth Biol, https://doi.org/10.1021/sb500356 , 2015). BASIC employs standardised DNA linkers to combine bioparts, stored in the universal BASIC format. Once a new biopart is formatted into BASIC standard, defined by flanking 18 bp prefix and suffix sequences, it can be placed at any position and in any context within a designed BASIC assembly. This modularity of the BASIC approach is further enhanced by a range of functional linkers, including genetic elements like ribosomal binding sites (RBS) and peptide linkers. The method has a single tier format, whereby any BASIC assembly can create a new composite BASIC part in the same format used for the original parts; it can thus enter a subsequent BASIC assembly without the need for reformatting or changes to the workflow. This unique idempotent cloning mechanism allows for the assembly of constructs in multiple, conceptionally simple hierarchical rounds. Combined with its high accuracy and robustness, this makes BASIC a versatile assembly method for combinatorial and complex assemblies both at bench and biofoundry scale. The single universal storage format of BASIC parts enables compressed universal biopart libraries that promote sharing of parts and reproducible assembly strategies across labs, supporting efforts to improve reproducibility. In comparison with other DNA assembly standards and methods, BASIC offers a simple robust protocol, relies on a single tier format, provides for easy hierarchical assembly, and is highly accurate for up to seven parts per assembly round (Casini et al., Nat Rev Mol Cell Biol. https://doi.org/10.1038/nrm4014 , 2015).


Assuntos
Clonagem Molecular/métodos , DNA/genética , Engenharia Genética/métodos , Vetores Genéticos/genética , Reprodutibilidade dos Testes , Projetos de Pesquisa , Biologia Sintética/métodos
13.
Synth Biol (Oxf) ; 4(1): ysz019, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-32995542

RESUMO

In vitro selection of ligand-responsive ribozymes can identify rare, functional sequences from large libraries. While powerful, key caveats of this approach include lengthy and demanding experimental workflows; unpredictable experimental outcomes and unknown functionality of enriched sequences in vivo. To address the first of these limitations, we developed Ligase-Assisted Selection for the Enrichment of Responsive Ribozymes (LigASERR). LigASERR is scalable, amenable to automation and requires less time to implement compared to alternative methods. To improve the predictability of experiments, we modeled the underlying selection process, predicting experimental outcomes based on sequence and population parameters. We applied this new methodology and model to the enrichment of a known, in vitro-selected sequence from a bespoke library. Prior to implementing selection, conditions were optimized and target sequence dynamics accurately predicted for the majority of the experiment. In addition to enriching the target sequence, we identified two new, theophylline-activated ribozymes. Notably, all three sequences yielded riboswitches functional in Escherichia coli, suggesting LigASERR and similar in vitro selection methods can be utilized for generating functional riboswitches in this organism.

14.
Nucleic Acids Res ; 46(22): 11980-11989, 2018 12 14.
Artigo em Inglês | MEDLINE | ID: mdl-30329088

RESUMO

NExo is an enzyme from Neisseria meningitidis that is specialized in the removal of the 3'-phosphate and other 3'-lesions, which are potential blocks for DNA repair. NExo is a highly active DNA 3'-phosphatase, and although it is from the class II AP family it lacks AP endonuclease activity. In contrast, the NExo homologue NApe, lacks 3'-phosphatase activity but is an efficient AP endonuclease. These enzymes act together to protect the meningococcus from DNA damage arising mainly from oxidative stress and spontaneous base loss. In this work, we present crystal structures of the specialized 3'-phosphatase NExo bound to DNA in the presence and absence of a 3'-phosphate lesion. We have outlined the reaction mechanism of NExo, and using point mutations we bring mechanistic insights into the specificity of the 3'-phosphatase activity of NExo. Our data provide further insight into the molecular origins of plasticity in substrate recognition for this class of enzymes. From this we hypothesize that these specialized enzymes lead to enhanced efficiency and accuracy of DNA repair and that this is important for the biological niche occupied by this bacterium.


Assuntos
Proteínas de Bactérias/química , Reparo do DNA , DNA Liase (Sítios Apurínicos ou Apirimidínicos)/química , Proteínas de Ligação a DNA/química , Exodesoxirribonucleases/química , Neisseria meningitidis/enzimologia , Domínio Catalítico , Cristalografia por Raios X , DNA/química , Dano ao DNA , Endonucleases/metabolismo , Mutagênese Sítio-Dirigida , Mutação , Neisseria meningitidis/genética , Estresse Oxidativo , Ligação Proteica , Conformação Proteica , Especificidade por Substrato
15.
Methods Mol Biol ; 1472: 79-91, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-27671933

RESUMO

Biopart Assembly Standard for Idempotent Cloning (BASIC) is a simple, accurate, and robust DNA assembly method. The method is based on linker-mediated DNA assembly and provides highly accurate DNA assembly with 99 % correct assemblies for four parts and 90 % correct assemblies for seven parts [1]. The BASIC standard defines a single entry vector for all parts flanked by the same prefix and suffix sequences and its idempotent nature means that the assembled construct is returned in the same format. Once a part has been adapted into the BASIC format it can be placed at any position within a BASIC assembly without the need for reformatting. This allows laboratories to grow comprehensive and universal part libraries and to share them efficiently. The modularity within the BASIC framework is further extended by the possibility of encoding ribosomal binding sites (RBS) and peptide linker sequences directly on the linkers used for assembly. This makes BASIC a highly versatile library construction method for combinatorial part assembly including the construction of promoter, RBS, gene variant, and protein-tag libraries. In comparison with other DNA assembly standards and methods, BASIC offers a simple robust protocol; it relies on a single entry vector, provides for easy hierarchical assembly, and is highly accurate for up to seven parts per assembly round [2].


Assuntos
Clonagem Molecular , Sequência de Bases , Escherichia coli/genética , Reação em Cadeia da Polimerase , Transformação Bacteriana
16.
ACS Synth Biol ; 4(7): 781-7, 2015 Jul 17.
Artigo em Inglês | MEDLINE | ID: mdl-25746445

RESUMO

The ability to quickly and reliably assemble DNA constructs is one of the key enabling technologies for synthetic biology. Here we define a new Biopart Assembly Standard for Idempotent Cloning (BASIC), which exploits the principle of orthogonal linker based DNA assembly to define a new physical standard for DNA parts. Further, we demonstrate a new robust method for assembly, based on type IIs restriction enzyme cleavage and ligation of oligonucleotides with single stranded overhangs that determine the assembly order. It allows for efficient, parallel assembly with great accuracy: 4 part assemblies achieved 93% accuracy with single antibiotic selection and 99.7% accuracy with double antibiotic selection, while 7 part assemblies achieved 90% accuracy with double antibiotic selection. The linkers themselves may also be used as composable parts for RBS tuning or the creation of fusion proteins. The standard has one forbidden restriction site and provides for an idempotent, single tier organization, allowing all parts and composite constructs to be maintained in the same format. This makes the BASIC standard conceptually simple at both the design and experimental levels.


Assuntos
Clonagem Molecular , DNA/metabolismo , Sequência de Bases , Desoxirribonucleases de Sítio Específico do Tipo II/metabolismo , Engenharia Genética , Oligonucleotídeos/química , Oligonucleotídeos/metabolismo , Reação em Cadeia da Polimerase
17.
Anal Chem ; 86(21): 10732-40, 2014 Nov 04.
Artigo em Inglês | MEDLINE | ID: mdl-25303623

RESUMO

Uracil DNA glycosylase plays a key role in DNA maintenance via base excision repair. Its role is to bind to DNA, locate unwanted uracil, and remove it using a base flipping mechanism. To date, kinetic analysis of this complex process has been achieved using stopped-flow analysis but, due to limitations in instrumental dead-times, discrimination of the "binding" and "base flipping" steps is compromised. Herein we present a novel approach for analyzing base flipping using a microfluidic mixer and two-color two-photon (2c2p) fluorescence lifetime imaging microscopy (FLIM). We demonstrate that 2c2p FLIM can simultaneously monitor binding and base flipping kinetics within the continuous flow microfluidic mixer, with results showing good agreement with computational fluid dynamics simulations.


Assuntos
DNA/química , Microscopia de Fluorescência/métodos , Nucleotídeos/química , Cor , Cinética , Fótons
18.
ACS Synth Biol ; 3(8): 525-8, 2014 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-24933158

RESUMO

R2oDNA Designer is a web application that stochastically generates orthogonal sets of synthetic DNA sequences designed to be biologically neutral. Biologically neutral sequences may be used for directing efficient DNA assembly by overlap-directed methods, as a negative control for functional DNA, as barcodes, or potentially as spacer regions to insulate biological parts from local context. The software creates optimized sequences using a Monte Carlo simulated annealing approach followed by the elimination of sequences homologous to host genomes and commonly used biological parts. An orthogonal set is finally determined by using a network elimination algorithm. Design constraints can be defined using either a web-based graphical user interface (GUI) or uploading a file containing a set of text commands.


Assuntos
DNA/química , DNA/genética , Software , Genoma , Método de Monte Carlo , Processos Estocásticos , Interface Usuário-Computador
19.
Nucleic Acids Res ; 42(1): e7, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24153110

RESUMO

Overlap-directed DNA assembly methods allow multiple DNA parts to be assembled together in one reaction. These methods, which rely on sequence homology between the ends of DNA parts, have become widely adopted in synthetic biology, despite being incompatible with a key principle of engineering: modularity. To answer this, we present MODAL: a Modular Overlap-Directed Assembly with Linkers strategy that brings modularity to overlap-directed methods, allowing assembly of an initial set of DNA parts into a variety of arrangements in one-pot reactions. MODAL is accompanied by a custom software tool that designs overlap linkers to guide assembly, allowing parts to be assembled in any specified order and orientation. The in silico design of synthetic orthogonal overlapping junctions allows for much greater efficiency in DNA assembly for a variety of different methods compared with using non-designed sequence. In tests with three different assembly technologies, the MODAL strategy gives assembly of both yeast and bacterial plasmids, composed of up to five DNA parts in the kilobase range with efficiencies of between 75 and 100%. It also seamlessly allows mutagenesis to be performed on any specified DNA parts during the process, allowing the one-step creation of construct libraries valuable for synthetic biology applications.


Assuntos
DNA/química , Análise de Sequência de DNA , Biologia Sintética/métodos , DNA/síntese química , Escherichia coli/genética , Genes Sintéticos , Plasmídeos/genética , Reação em Cadeia da Polimerase , Saccharomyces cerevisiae/genética , Software , Biologia Sintética/normas
20.
Proc Natl Acad Sci U S A ; 109(42): 16852-7, 2012 Oct 16.
Artigo em Inglês | MEDLINE | ID: mdl-23035246

RESUMO

Base excision repair (BER) is a highly conserved DNA repair pathway throughout all kingdoms from bacteria to humans. Whereas several enzymes are required to complete the multistep repair process of damaged bases, apurinic-apyrimidic (AP) endonucleases play an essential role in enabling the repair process by recognizing intermediary abasic sites cleaving the phosphodiester backbone 5' to the abasic site. Despite extensive study, there is no structure of a bacterial AP endonuclease bound to substrate DNA. Furthermore, the structural mechanism for AP-site cleavage is incomplete. Here we report a detailed structural and biochemical study of the AP endonuclease from Neisseria meningitidis that has allowed us to capture structural intermediates providing more complete snapshots of the catalytic mechanism. Our data reveal subtle differences in AP-site recognition and kinetics between the human and bacterial enzymes that may reflect different evolutionary pressures.


Assuntos
Reparo do DNA/genética , DNA Liase (Sítios Apurínicos ou Apirimidínicos)/química , DNA Liase (Sítios Apurínicos ou Apirimidínicos)/metabolismo , DNA/metabolismo , Modelos Moleculares , Neisseria meningitidis/genética , Cristalografia por Raios X , DNA/química , Furanos , Humanos , Estrutura Molecular , Neisseria meningitidis/metabolismo , Conformação Proteica , Dobramento de Proteína
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...